Defining Bar Code Fields ––––––––––––––––––––––––––––––––––––

Example

B,3,12,V,150,40,1,2,80,7,L,0

p

Syntax

B,field#,# of char,fix/var,row,column,font,
density,height,text,alignment,field rot

p

B1. B

Indicates bar code field. Enter B.

B2. field #

Unique number from 0-99 to identify this field. (Pitney
Bowes recommends starting at 1, instead of 0.)

B3. # of char

Maximum number of characters. Range: 1-2710.

B4. fix/var

Fixed or variable length field. Options:

F

Fixed length

V

Variable length field.

B5.row

Distance from bottom of print area to lower left corner of
the field. (The bottom exits the printer first.) Ranges:

English

0 - 599

Metric

0 - 1523

Dots

0 - 1151

B6. column

Distance to the lower left corner of the field from the left
edge of print area. Ranges:

English

0 - 399

Metric

0 - 1014

Dots

0 - 767

J640 Programmer’s Manual