Defining the Communication Settings Record F –––––––––––––––––

Changing the communication settings takes approximately two
seconds to complete. Communications during this interval
may be lost. Always make sure the communications values at
the host match the values on your printer, or you will not be
able to print formats.

Example

{I,F,3,0,0,0,0

p

}

Syntax

{I,F,baud,word_length,stop_bits,parity,
flow_control

p

}

F1. F

Indicates the Communication Settings Record

F2. baud

Options:

0

1200

1

2400

2

4800

3

9600 (default)

4

19.2K

F3. word_length

Options:

0

7-bit data frame

1

8-bit data frame (default)

F4. stop_bits

Options:

0

1-stop bit (default)

1

2-stop bits

F5. parity

Options:

0

none (default)

1

ODD parity

2

EVEN parity

F6. flow_control

Options:

0

None

1

DTR (default)

2

CTS/RTS

3

XON/XOFF

Syn

tax Q

u

ick Ref

e

ren

ce

Chapter 7. Syntax Quick Reference