Alarm control, Alarm mode, Operating during an alarm mode – Panasonic WJ-SX 150 User Manual

Page 100: Operation of an alarm-related camera (ack), Alarm01 ack

Advertising
background image

102

Operating during an Alarm Mode

While an alarm mode is active, the following are available
from the system controller:

• Operating the camera with the alarm input (ACK)
• Resetting the alarm (RESET/ALL RESET)
• Suspending the alarm (ALM SUSPENDED)

Operation of an Alarm-related
Camera (ACK)

You can operate the camera with the alarm input as follows:

1. Select a monitor which displays "ALARM".
2. Press the ACK button.

"ACK" will appear on the monitor with an alarm input.
The camera with an alarm input will become operable.

3. Operate camera with the system controller.

Pan/Tilt, zoom, focus, and iris are available.
When selecting another monitor, "ACK" will disappear
from the display. The matrix switcher system will return
to the alarm mode.

MON LOCK

DEF ON

WIPER

DEF OFF

MON (ESC)

T&D

CAM ID

MON STATUS

ALL

EVENT

ALM H

VLD H

SYS S

CAM (SET)

MULTI SCREEN SEL

SEQUENCE

AUX2 ON

AUX2 OFF

EL-ZOOM

AUX1 ON

AUX1 OFF

STILL

SHIFT

REW/FF

STEP

GROUP SEQ

PAUSE

SUSPEND

ALL RESET

ACK

RESET

TOUR SEQ

PREV

NEXT

OSD

PLAY

PAUSE

Alarm Mode

When alarm (sensor) is accepted, the matrix switcher's
operation mode changes to the alarm mode. Then, the sys-
tem operates as follows:

• The camera image (alarm image) appears on the moni-

tor.
In the factory default setting, the alarm inputs 1 to 16
are associated with the same-numbered camera input
connectors. All the video output signals are sent to
Monitor 1. For example, when the alarm (sensor) con-
nected to the alarm input 1 becomes active, the camera
input connector 1’s image appears on Monitor 1.

• "ALARMnn" appears on the monitor.

The display indicates the image is input through the
alarm nn (nn is the alarm number).
When more than one alarm signal input has been
accepted, "ALARMnn

*

" appears on the monitor.

• Alarm output signals are supplied from Alarm Output 1

to 4 (#10, 11, 23 and 24) of the ALARM port (25-pin D-
sub connector) at the rear panel. Alarm Output 1 to 4 is
associated with MONITOR OUT 1 to 4. For example,
when an alarm input signal is activated on MONITOR
OUT 1, the unit supplies Alarm Output 1 to Monitor 1.

• The monitor and alarm number will appear on the LED

display. At the same time, the alarm indicator will blink,
the monitor indicator will light up, and the camera indi-
cator will go out.

There are two operation mode when more than one
alarm signal has been accepted by the unit that is
assigned to the same monitor.

• Sequence mode:

An alarm operation is replaced by

another one after the dwell time ends.

• Hold mode:

An initial alarm operation is continued

even after another alarm input is accepted.

Notes:

• The association of the alarm inputs with cameras and

monitors are changeable in SETUP MENU or WJ-SX150
Administrator Console. (Refer to p. 56 or p. 74.)

• Alarm input will be automatically reset in 30 seconds.

The auto-recovery time is configurable through SETUP
MENU or WJ-SX150 Administrator Console.

ALARM CONTROL

ALARM01

ACK

Advertising