108

WHEN USING A PS·DATA SYSTEM CONTROLLER

This manual describes the operating procedures which are specifically related to WJ-SX150.
For the basic operating procedures such as log-in/log-out, camera selection, and camera control, etc., refer to the system con-
troller's operating instructions.
The following are different from the terminal mode when you use the system controller via the PS·Data protocol.

• Camera selection, camera control, camera site accessories control are in accordance with the PS·Data System operating

procedures. Refer to the system controller's operating instructions.

• You cannot reset an alarm one by one per monitor. However, you can reset all the alarms at a time (ALL RESET).
• You cannot acknowledge an alarm.
• You cannot use the auto log-in function of the unit. To use this function, use a terminal-mode system controller.
• You cannot use the auto log-out function of the unit.
• You cannot move the clock, camera title, event, and/or monitor status display with a PS·Data controller. Use a terminal-

mode system controller.

• Operators using the PS·Data system controller have the highest priority to all those using the terminal-mode system con-

trollers.

• PS·Data doesn’t support user-management, and you cannot configure the PS·Data operator registration neither through

SETUP MENU nor WJ-SX150 Administrator Console.

Notes:

• When you select a monitor with a PS·Data system controller, you might enter its number as you do in the terminal mode.

However, the matrix switcher regards a monitor as a unit, you need to select it by the unit number. (Refer to p. 109.)

• This unit is counted as 4 PS·Data units. Confirm the total number of the PS·Data units in your system.

(Up to 16 PS·Data units are available.)