• It is also selectable whether to activate the recording

and sequence/spot image monitoring when an alarm
signal is input to the unit. Alarm recording without the
sequence/spot image monitoring is also available.

●

Operator Settings

If you control this unit with a terminal-mode system con-
troller, your operator information, controllable monitors and
auto log-in/log-out will be registrable and configurable.

• Operator registration: Up to 16 operators are available.

ID and password for operator identification are config-
urable. Level and priority can be assigned to each
operator. Each camera's control coverage is also con-
figurable.

• Level table: Restriction level for each password is cus-

tomizable.

• Monitor select (Monitor selection): Controllable monitor

can be assigned to each controller.

• Auto login/logout (Auto log-in/log-out): Auto log-in/log-

out is configurable for each controller.

Notes:

• These settings (except Operator registration) are con-

figurable only through WJ-SX150 Administrator
Console. Operator registration is configurable through
SETUP MENU and WJ-SX150 Administrator Console.

• When you control the unit with a PS·Data system con-

troller, the above settings will be invalid. Refer to the
system controller's operating instructions.

●

System Settings

SETUP MENU can configure the clock (time and date),
cable compensation and camera title.
Besides these settings, WJ-SX150 Administrator Console
can select the data ports' baud rates.

• Clock (Time and date): The unit's time and date are

configurable.

• Cable compensation: Cable compensation type is

selectable depending on the distance between a cam-
era and the unit. It is also possible to determine whether
to send the VD2 timing pulse or control data with the
camera output signals.

• Camera title: Camera title is configurable to identify the

camera images on the monitor. WJ-SX150 Administrator
Console can configure the camera title including origi-
nal characters.

• Data port: Usually, the ports DATA 1 to 3 connect to the

terminal-mode system controllers. RS-485 cameras will
be connectable with the data port configurations
through WJ-SX150 Administrator Console and SETUP
MENU.
When you use the system controllers via the PS·Data
protocol, you need to configure the DATA 4 port setting
through SX150 Admin Console or SETUP MENU.

• EXT IN: External synchronization of the EXT IN connec-

tor is set to ON or OFF.

●

Multiplexer

• Recorder: The type and unit address of the recorder

are configurable.

• MULTIPLEXER: The parameters of the recorder mode

are configurable. You can set the alarm and normal
recording rate. You can also activate/deactivate
dynamic recording, dummy black, and CAM SW LOSS”
indication.

• MUX (Multiplxer) CAMERA TITLE: Camera titles which

are displayed with Multiscreen segments are config-
urable.

●

Setup File Operation

WJ-SX150 Administrator Console can send a configuration
file from the PC to this unit. The utility can also send the file
from the unit to the PC for configuration.

• Put to a file: A configuration data is sent from the PC to

the unit.

• Get from a file: A configuration data is sent from the unit

to the PC.

• Select setup data file: A configuration data is selected

when sending it from the PC to the unit (or from the unit
to the PC.)

Note:

These settings are configurable only through WJ-

SX150 Administrator Console.

●

WJ-SX150 Administrator Console
Configuration

The PC-related settings are configurable.

• Account Manager: WJ-SX150 Administrator Console

operators are registrable and changeable.

• Communication (Serial) port: PC's usable communica-

tion port number and its baud rate (communication
speed) are configurable.