Alarm event, Alarm port – Panasonic WJ-SX 150 User Manual

Page 72

Advertising
background image

74

• Alarm Reset Time

Select the time to reset the alarm input.
The selectable time: OFF (not resetting the alarm), 10, 20,
30, 40, 50, 60, 120 or 180 (seconds)
The factory default setting is 30 sec.

(Save Exit) button

Saves the configuration and closes the Alarm Mode win-
dow.

(Cancel Exit) button

Cancels the configuration and closes the Alarm Mode win-
dow.

Alarm Event

This window configures the details of operation parameters
when an alarm signal is input: the monitor and mode to dis-
play the alarm image, and the preset position of the cam-
era. Up to 16 alarm inputs are configurable.

How to Display

To display this window, click on the

(Alarm Event) but-

ton in the main window (p. 65).

Parameters

Mon (Monitor)

Select the monitor to display the alarm image.

Spot/Tour

Select the spot camera number or the tour sequence num-
ber.

Cam 1 to 16:

To display a spot picture, select a camera

number.

Tour 1 to 16:

To execute a tour sequence, select a tour

number.

Pre (Preset Position Number)

Select the preset position of the camera when selecting the
spot camera number in Spot/Tour. Position 1 to 64 is selec-
table for Pre. When the camera is not equipped with the
preset position function, select "--".

Notes:

• If having selected a tour sequence for a monitor, anoth-

er tour number or spot camera will not be available
when selecting the monitor for another alarm event.
That will result in an error.

• In the factory default setting, Tour 1 to 4 is selectable.

To select Tour 5 to 16, you need to configure the tour
sequences in the Tour Sequence window. (Refer to p.
68.)

(Save Exit) button

Saves the configuration and closes the Alarm Event win-
dow.

(Cancel Exit) button

Cancels the configuration and closes the Alarm Event win-
dow.

Alarm Port

This window configures the parameters of alarm inputs.

How to Display

To display this window, click on the

(Alarm Port) but-

ton in the main window (p. 65).

Parameters

• Alarm Port Group

Select the desired alarm input parameter in each alarm
port's drop-down menu.

N.O. :

Normally Open

N.C. :

Normally Close

• Time Adjust Box

Select the alarm port to assign to the time adjustment.
When not assign any port to time adjustment, select None.

(Save Exit) button

Saves the configuration and closes the Alarm Input window.

(Cancel Exit) button

Cancels the configuration and closes the Alarm Input win-
dow.