Data port – Panasonic WJ-SX 150 User Manual

Page 79

Advertising
background image

81

Data Port

This window configures the parameters of each data port
(RS485, DATA 1 to 4 and DATA HDR port): the protocol, the
baud rate (communication speed), and the connected
cameras.

How to Display

To display this window, click on the

(Data Port) button

in the main window (p. 65).

Parameters

• RS-485 Port Group

Protocol:

Select RS485 when an RS-485 camera is

connected to the data port.
Select CU360C when the system controller is con-
nected to the data port.
Select PSD when the system controller is connected
to the DATA 4 port via the PS·Data protocol.
PS·Data mode will appear in the window.

Note:

The baud rate of DATA HDR is the same as

that of PSD. When you select PSD for DATA 4,
DATA HDR and its baud rate are displayed in
gray and not configurable. When you select
CU360C for DATA 4, DATA HDR and its baud
rate are configurable.

Baud Rate:

Select the desired baud rate (communica-

tion speed). 4800, 9600 or 19200 bps is selectable.

RS485 Camera Daisy (RS-485 Camera Daisy):

Select

the number(s) of the camera(s) connected to the
RS-485 daisy chain.
Data 1 to 3 are connectable to either of cameras
and system controllers.
When connecting cameras to these ports, select the
connected camera number(s).

PS·Data mode:

This stands for the PS·Data parameters

of the DATA 4 port.

Logout Time:

Select the desired operable time

before logout. OFF,10, 20, 30, 60, 90 or 120 sec
is available.
The factory default setting is 30 sec.

Alarm Data:

Select the desired time to accept an

alarm input signal. OFF, 0, 1 or 5 sec is avail-
able.
The factory default setting is 1 sec.

Wait Time:

Select the desired wait time to transmit

an alarm output signal. OFF, 100msec, 200m
sec, 400m sec or 1 sec is available.
The factory default setting is OFF.

Group Address:

This parameter is only for confir-

mation. Leave as it is.

• Fixed Common Parameter Group

The data bit (8 bit), parity (none), and stop bit (1 bit) are
displayed. These parameters are fixed.

(Save Exit) button

Saves the configuration and closes the Data Port window.

(Cancel Exit) button

Cancels the configuration and closes the Data Port window.

Advertising