Connection with the alarm output, Buzzer, Ext in multi screen out data hdr monitor out – Panasonic WJ-SX 150 User Manual

Page 40

Advertising
background image

41

Connection with Digital Disk
Recorder WJ-HD500 Series

Note

: Refer to a service manual procurable in your area, for

details on the connection with a recorder (after the net-
work board installation) to operate via LAN or the
Internet.

To Confirm the Images from a Recorder
Connected to the Unit

The following is the description of the connection between a
recorder and this unit to confirm the images from the
recorder.

1. Set the unit address of the recorder to 1. Then, confirm

that the recorder’s CAMERA GENLOCK is set to OFF in
its SETUP MENU. (Refer to the recorder's operating
instructions.)

2. Connect the unit’s CAM OUT 1 to 16 connectors to the

recorder’s VIDEO IN 1 to 16 connectors with a coaxial
cable.

3. Connect the unit’s EXT IN connector to the recorder’s

MULTI SCREEN OUT connector with a coaxial cable.

4. Connect the unit’s DATA HDR connector to the

recorder’s DATA port with a modular cable.
(The control data and alarm signal will be output from
the unit to the recorder.)

5. After the connection, set the unit’s EXT IN to GENLOCK

ON through SETUP MENU or WJ-SX150 Administrator
Console (Refer to pp. 60 or 66).

WJ-SX150 Matrix Switcher

Monitor

WJ-HD500 Series Digital Disk Recorder

16

16

15

15

14

14

13

13

12

12

11

11

10

10

9

9

8

8

7

7

6

6

5

5

4

4

3

2

2

3

1

1

SIGNAL GND

10/100

BASE-T

SPOT

OUT

IN

EXT STORAGE

COPY

CONTROL

ALARM

VIDEO

MODE

DATA

REMOTE(WV-CU50)

GEN-LOCK OUT

SERIAL

IN

OUT

OUT

MULTI SCREEN OUT

AUDIO

CAMERA

1

1

2

2

3

3

2

DATA 3 DATA 2

SERIAL

ALARM

TERM

OFF

ON

4

2

1

4

3

EXT OUT

(REC OUT)

CAMERA

SW IN

RS485(CAMERA)

LINE

SELECT

MONITOR OUT

EXT IN

(PLAY IN)

OUT

IN

4

4

5

5

6

6

7

7

8

8

9

9

10

10

11

11

12

12

13

13

14

14

15

15

16

16

RS485(CAMERA)

PS•DATA

DATA 4

DATA HDR

DATA 1

EXT IN

MULTI SCREEN
OUT

DATA HDR

MONITOR
OUT

Connection with the Alarm Output

Pins #10, 11, 23 and 24 (open collector) turns to 0 V while
the alarm is activated. These terminals can drive external
warning devices such as a buzzer or lamp of up to 100 mA,
16 V DC. If the rating exceeds 100 mA, 16 V DC use a relay
as shown in Example 2.
Alarm signals are output from the terminals until the reset.

Example 1:

Direct drive connection

Example 2:

Connection of devices exceeding drive

NO

C

NC

To Buzzer

Relay

+12V

GND

NC: Normally Closed Contact
NO: Normally Open Contact
C:

Common

Buzzer

Advertising