Multiplexer mode – Panasonic WJ-SX 150 User Manual

Page 80

Advertising
background image

82

■

Multiplexer Mode

●

How to Display

Note:

This window can be displayed only when “Yes” is

selected in the Recorder window. (Refer to p. 66.)

●

Parameters

To display this window, click on the

(Multiplexer

Mode) button in the main window (p. 65.)

• Multi Monitor Out Group

Still Display:

Select the desired setting by clicking on

the drop-down menu.

ON:

Still picture is available during the multiscreen dis-

play.

OFF:

Still picture is not available during the multiscreen

display.

The factory default setting is ON.

Border Color:

Select the desired setting by clicking on

the drop-down menu. This setting will determine the
color of the border which separates each multi-
screen segment.

WHITE:

The border will be displayed in white.

GRAY:

The border will be displayed in gray.

BLACK:

The border will be displayed in black.

OFF:

No border will be displayed.

The factory default setting is WHITE.

Quad Shift:

Select the desired setting by clicking on

the drop-down menu.

ON:

Camera images are displayed in 4 multiscreen

segments (quad) and switched as follows:

4A = Page 1 of the quad (Camera 1, 2, 3 and 4)
4B = Page 2 of the quad (Camera 5, 6, 7 and 8)
4C = Page 3 of the quad (Camera 9, 10, 11 and

12)

4D = Page 4 of the quad (Camera 13, 14, 15 and

16)

OFF:

Quad is unavailable.

The factory default setting is OFF.

Secret View:

Select the desired setting by clicking on

the drop-down menu.

ON:

The drop-down menu becomes also active so that

you can select the desired monitor among MON 1
to 4. For example, when you select MON 1, other
operators, whose priority is lower than you, cannot
view the monitor (secret view).

OFF:

Secret view function is unavailable.

The factory default setting is OFF.

Sequence Mode:

Select the sequence type by clicking

on the radio button.

Quad:

Multiplexer sequence is activated. The monitor

display will be changed as 4A

→

4B

→

4C

→

4D.

3+1:

Images are displayed in 4 multiscreens, and the

images of Camera 4 to 16 are displayed in the
sequence mode, at the right bottom of the monitor.
The images of Camera 1 to 3 are fixed. (Refer to the
left-side illustration in p. 19.)

8+1:

Images are displayed in 9 multiscreens, and the

images of Camera 9 to 16 are displayed in the
sequence mode, at the right bottom of the monitor.
The images of Camera 1 to 8 are fixed. (Refer to the
right-side illustration in p. 19.)

The factory default setting is Quad.

Dwell:

The dwell time of the selected sequence mode

is selectable. 2S to 30S is available.

The factory default setting is 2S.

• REC OUT Group

Title Display:

Select the desired setting by clicking on

the drop-down menu.

ON:

The camera title is displayed on the recorded

image.

OFF:

The camera title is not displayed on the recorded

image.

The factory default setting is ON.

Clock Display

: Select the desired setting by clicking on

the drop-down menu.

ON:

The date and time are displayed on the recorded

image.

OFF:

The date and time are not displayed on the

recorded image.

The factory default setting is ON.

Normal Group

REC Mode:

Select the desired setting by clicking on

the radio button.

EXT:

Select this to gen-lock the unit during the normal

recording.

INT:

Select this if the asynchronous unit is connected to

the unit. When it is activated, the drop-down menu
becomes also active so that you can select the
desired normal recording rate. 002, 004 to 255
(field) are selectable.

The factory default setting is EXT.