Mux camera title – Panasonic WJ-SX 150 User Manual

Page 61

Advertising
background image

63

MUX CAMERA TITLE

How to Display

This menu will appear only when the Multiplexer board is
installed in the unit. To display this menu on the monitor,
move the cursor to 1000 MUX CAMERA TITLE in SETUP
MENU by moving the joystick to D or C. Then, press the
CAM (SET) button. The submenu appears monitor.

How to edit

The factory default settings are same as illustrations.
The editing procedure is the same as 500 CAMERA TITLE.
(Refer to p. 59.)

Notes:

• Up to 8 alphanumeric characters are available for

each multiplexer board camera title.

• When moving the joystick to D at the last text box

of CAM 8 TITLE, the cursor will move to the first text
box of CAM 9 TITLE.

• When moving the joystick to C at the first text box

of CAM 9 TITLE, the cursor will move to the last text
box of CAM 8 TITLE.

1000 MUX CAMERA TITLE

CAM TITLE CAM TITLE
1 C01 9 C09
2 C02 10 C10
3 C03 11 C11
4 C04 12 C12
5 C05 13 C13
6 C06 14 C14
7 C07 15 C15
8 C08 16 C16

Parameters

Move the joystick to move the cursor.
Press the NEXT or PREV button to select the desired para-
meters.

• ALARM

EXT:

Select this to gen-lock the unit with the recorder

when an alarm is input to the unit.

002,004 to 128 (field):

Select one of these alarm

recording rates if the asynchronous unit is connect-
ed to the unit.

The factory default setting is EXT.

• NORMAL

EXT:

Select this to gen-lock the unit during the normal

operation.

002,004 to 255 (field):

Select one of these normal

recording rates if the asynchronous unit is connect-
ed to the unit.

The factory default setting is EXT.

• DYNAMIC REC

PRI.:

Select this to give recording priority to the camera

channel with the alarm input.

ONLY:

Select this to record the images from the alarm-

associated camera channel.

GROUP:

Select this to give recording priority to a group

of up to 4 camera channels associated to the alarm
input.

OFF:

Select this to deactivate the alarm priority mode.

The factory default setting is OFF.

• DUMMY BLACK

ON:

Select this to display the black picture for a cam-

era channel that is not connected to the camera.

OFF:

Select this to skip the camera channels that are

not connected to the camera in the sequence/spot
mode.

The factory default setting is ON.

• CAM SW LOSS

ON:

Select this to make “SW LOSS” blinking on the

associated monitor when loss of the camera switch-
ing pulse is detected.

OFF:

Select this not to make “SW LOSS” appear on the

associated monitor when loss of the camera switch-
ing pulse is detected.

The factory default setting is ON.

Note:

If EXT is selected for 910 ALARM/920 NORMAL,

the playback images cannot be displayed on the
monitors which are not connected to the EXT IN
connector. Confirm the images on those which are
connected to the recorder.