Inspecting the Memory Recording
Functions

Make sure you successively carry out the inspections from
[Inspecting the P2 Card Recording] to [Inspecting the
Earphone and Speaker].

Inspecting the P2 Card Recording

1



CheckontheLCDmonitororintheviewfinder

thattheremainingPcardrecordingcapacity

forbothPcardsissufficient.

For details, refer to [Screen Displays] (page 68).

2



Pressthecamera’sRECbuttontocheckthe

followingitems:

• The P2 card access LEDs blink in orange.
• The REC indication on the screen lights.
• System warnings do not appear on the screen.

3



Pressthecamera’sRECbuttonagain.

• Check that the P2 card access LEDs light in

orange, and that the REC indication on the screen
is cleared.

4



UsingtheRECbuttononthehandle,repeat

Stepsto3tocheckthesameoperation.

5



UsingtheRECbuttononthelensunit,repeat

Stepsto3tocheckthesameoperation.

6



PresstheTHUMBNAILbuttontoswitch

thethumbnailscreentoplaybackcurrently

recordedclipfromthumbnail.

• Check that playback is operating normally.

Inspecting the Audio Level Automatic
Adjustment

1



SettheAUDIOSELECTCH1andCH

switchestoAUTO.

2



SettheAUDIOINswitchtoFRONT.

3



AimthemicrophoneconnectedtotheMICjack

atanappropriatesoundsource.Then,check

thattheleveldisplaysforbothCH1andCH

changeaccordingtothesoundlevel.

Inspecting the Audio Level Manual
Adjustment

1



SettheAUDIOINswitchtoFRONT.

2



SettheAUDIOSELECTCH1andCH

switchestoMAN.

3



TurntheAUDIOLEVELCH1andCHcontrols.

• Check that the level display increases when the

controls are turned to the right.

Inspecting the Earphone and Speaker

1



TurntheMONITORcontroltocheckthatthe

speakervolumechanges.

2



ConnectanearphonetothePHONESjack.

• Check that the speaker is turned off and the

microphone sound can be heard from the
earphone.

3



TurntheMONITORcontroltocheckthatthe

earphonevolumechanges.