Warning system, Warning description tables – Panasonic AG-3DP1G User Manual

Page 127

Advertising
background image

1

Chapter


Maintenance

and

Inspections

Warning System

Warning Description Tables

If a problem is detected immediately after the power is turned on, or during operation, this will be indicated by the
WARNING lamp, lamps on the LCD monitor and a warning tone.
Warnings have priorities. If multiple errors occur simultaneously, the WARNING lamp, warning display on the screen, and
alarm tone are displayed in order of priority shown in the table below.

Priority

Warning

type

LCD indication

Tally lamp

WARNING

lamp

Alarm

tone

*

1

Warning description

and recording/playback

operation

Countermeasures

1 System error

SYSTEM ERROR cause
indication

*

2

blinks red.

Blinks 4
times per
second

Blinks 4
times per
second

Continuous
tone

Reference signal or
communication error.
Operation stops.

Check the cause
indication

*

2

and consult your
distributor.

2

Incorrect
P2 card
removal

TURN POWER OFF
Blinks red

Blinks 4
times per
second

Blinks 4
times per
second

Continuous
tone

A P2 card was removed
during access and card data
was corrupted.
Both P2 card access LEDs
blink in orange. Recording/
playback cannot start.

Turn off the power.
Repair the P2 card if
the clips on the card
are corrupted.

3

The
battery is
exhauseted

LOW BATTERY blinks
red, and the battery level
bar blinks with the empty
status. (This indication
appears even if CARD/
BATT is set to OFF in the
DISPLAY SETUP screen.)

Blinks 1 time
per second

Lights

Continuous
tone

The battery is exhausted.
Recording and playback
stop. The camera stops
automatically when the
voltage drops.

Replace the battery.

4

Version
mismatch

VERSION MISMATCH
PLEASE UPDATE
Blinks white

Blinks 4
times per
second

Blinks 4
times per
second

No

Version misatch has occurred.
Only SD CARD FORMAT and
UPDATE are available with the
thumbnail menu.

Perform CARD
UPDATE.

5

High
Temperature
error
detectionl

HIGH TEMPERATURE
Blinks red

Off

Off

No

High temperature error
is detected. Operation
continues, but abnormal
recording/playback may
occur.

Stop operation
immediately
and consult your
distributor.

6 Fan stop

FAN STOPPED cause
indication

*

3

blinks red

Off

Off

No

The fan is in failure and has
stopped. Although operation
continues with the fan
stopped, it may raise the
temperature inside the unit,
causing abnormal recording/
playback.

Check the cause
indication

*

3

and

consult your
distributor.

(Continued on the next page)

*

1

When the alarm sounds, audio is not output to the camera speakers or earphones. The DISP/MODE CHK button

cancels only the alarm tone when pressed during an alarm.

*

2

P2 SYSTEM ERROR cause indication

• P2 MICON ERROR: The P2 microprocessor does not respond.
• P2 CONTROL ERROR: A P2 recording control error has occurred.
• CAM MICON ERROR: The camera microprocessor does not respond.
• P2 MICON LINK ERROR: A connection error between P2 microprocessors has occurred.

*

3

FAN STOPPED cause indication

• FAN: FAN error position (1, 1/2, 1/3, 2, 2/3, 3, 1/2/3)

Advertising