ProSafe Dual Band Wireless Access Point WNDAP330 Reference Manual

3-2

Management

v1.0, May 2008

2. Enter the following information in the SNMP fields:

SNMP: Enable SNMP to allow the SNMP network management software, such as HP
OpenView, to manage the wireless access point via SNMPv1/v2 protocol.

Read-Only Community Name: The community string to allow the SNMP manager to
read the wireless access point's MIB objects. The default is Public.

Read-Write Community Name: The community string to allow the SNMP manager to
read and write the wireless access point's MIB objects. The default is Private.

Trap Community Name: The community string to allow the SNMP manager to send
traps. The default is trap.

IP address to Receive Traps: The IP address of the SNMP manager to receive traps sent
from the wireless access point. The default is 0.0.0.0.

Remote Console

The Remote Console configuration features are located under the Maintenance tab, Remote
Management, and then under Remote Console. Enter the following information in the Remote
Console screen, as shown in

Figure 3-2

:

Secure Shell (SSH): If set to Enable, the Wireless Access Point will only allow remote
access via Secure Shell and Secure Telnet. The default is Enable.

Telnet: If set to Enable, the Wireless Access Point will only allow remote access via
Telnet. The default is Enable.