Nortel Networks LIP-6830 User Manual

Page 115

Advertising
background image

LIP-6812 & LIP-6830

Installer Guide

Rev. 01.04

D-

7

June

07

Valid values are 50 through 300 ms. The default is 120.

frame_duration

(Optional) RTP frame duration in milliseconds.
Valid values are 10 to 100.
Default is 20.

headset_mode

(Optional) Whether or not the headset mode is enabled. When
enabled, the headset will be selected as the preferred
transducer.
Valid values are disable and enable.
Default is disable.

dtmf

(Optional) RFC 2833 payload type for DTMF signals.
Valid values are as follows:

inband — Always generate in-band DTMF.

• nego — Negotiate RFC2833 out-of-band and in-band

with remote side.

• rfc2833 — Always generate DTMF digits out-of-band

RFC2833.

• info — Always generate DTMF digits out-of-band INFO

message.

Default is nego.

ringtype0

(Optional) Two value frequency array, 0 to 4000 Hz.
Default is 425 440

ringtype1

(Optional) Two value frequency array, 0 to 4000 Hz.
Default is 530 555

ringtype2

(Optional) Two value frequency array, 0 to 4000 Hz.
Default is 350, 375

ringtype3

(Optional) Two value frequency array, 0 to 4000 Hz.
Default is 1280, 1300

ringtype4

(Optional) Two value frequency array, 0 to 4000 Hz.
Default is 490, 500

ringtype5

(Optional) Two value frequency array, 0 to 4000 Hz.
Default is 690, 700

ringtype6

(Optional) Two value frequency array, 0 to 4000 Hz.
Default is 1090, 1100

cadence0

(Optional) Ring cadence when undefined in Alert Info header.
Six value time array (on off on off on off). Valid range is 0 to
30000 milliseconds.
Default is 2000 4000 0 0 0 0.

cadence1

(Optional) Ring cadence when External call in Alert Info
header. Six value time array (on off on off on off). Valid range
is 0 to 30000 milliseconds.
Default is 800 400 800 4000 0 0.

cadence2

(Optional) Ring cadence when Group call in Alert Info header.
Six value time array (on off on off on off). Valid range is 0 to
30000 milliseconds.
Default is 400 200 400 200 800 4000.

cadence3

(Optional) Ring cadence when Internal call in Alert Info
header. Six value time array (on off on off on off). Valid range
is 0 to 30000 milliseconds.
Default is 300 200 1000 200 300 4000

cadence4

(Optional) Ring cadence when ACD call in Alert Info header.
Six value time array (on off on off on off). Valid range is 0 to
30000 milliseconds.
Default is 500 0 0 0 0 0

cadence5

(Optional) Ring cadence when ACD call in Alert Info header.
Six value time array (on off on off on off). Valid range is 0 to
30000 milliseconds.
Default is 1000 100 1000 2000 0 0

Advertising