prog

(Optional) Specifies the flexible key number.
Valid values are as follows when the max line number is 2
(default value):

LIP-6812 phone — 2 to 11

LIP-6830 phone — 2 to 24

func

(Optional) Specifies the function to assign.
Valid values are as follows:

1 — Speed Dial

2 — Phonebook

3 — Call Log

4 — Headset

5 — Redial

6 — Redial

7 — Return

8 — FWRD

9 — CONF

10 — TRNS

11 — Hold

12 — DND

13 — Ringer Off

14 — Message

PROG

add

num

(Optional) Specifies the number to dial when the parameter
func is defined as 1(Speed Dial).

caller_id_blk

(Optional) Configures caller ID blocking. When enabled, the
phone blocks its own ID.
Valid values are enable and disable.
Default is disable.

anonymous_call_blk

(Optional) Enables or disables blocking of anonymous
incoming calls. Valid values are enable or disable. The default
is disable.

call_waiting

(Optional) Configures call waiting for incoming call.
Valid values are enable and disable.
Default is enable.

call_waiting_tone

(Optional) Enables or disables call waiting tone for every call.
Valid values are enable and disable.
Default is enable.

call_hold_ringback

(Optional) If you have a call on hold and are talking on another
call, when you hang up the call, this parameter causes the
phone to ring, letting you know that you still have another
party on hold.
Valid values are enable and disable.
Default is enable.

msg_waiting_tone

(Optional) Enables or disables a stutter dial tone when there is
a message waiting.
Valid values are enable and disable.
Default is enable.

auto_answer

(Optional) Enables or disables answering automatically an
incoming call.
Valid values are enable and disable.
Default is enable.

call_direct

(Optional) Enables Hotline/Warm-Line operation.
Valid values are enable or disable.
Default is disable.

call_direct_number

(Optional) Destination for direct call.

CALL

call_direct_timer

(Optional) Delay timer for Warm-Line operation.
Valid values are 0 to 10 seconds delay.

Advertising