Web OS 10.0 Application Guide

Chapter 7: Filtering

n

181

212777-A, February 2002

3.

Set the

timewin

parameter and calculate the total time window in seconds.

The total time window is a multiple of

fastage

(for information on

fastage

, see the Con-

figuration chapter in the Web OS 10.0 Command Reference). The total time window is calcu-
lated with the following equation:

Total Time window =

timewin

x

fastage

If the default value for

fastage

is 1 second, then the configured total time window is 3 sec-

onds.

N

OTE

From Step 2 and 3, the TCP rate limit defined as the maximum number of connections

over a specified time window is 30 TCP connections for every 3 seconds (or 10 TCP connec-
tions per second).

For a small site, 30 TCP connections per second provides a good indication if your site is being
attacked. The default is 100 TCP connections per second. For larger sites, TCP rate limit
greater than 2550 connection per second indicates the possibility that your switch is under
attack.

4.

Set the

holddur

parameter and calculate the hold down time in minutes.

The hold down time is a multiple of

slowage

(for information on

slowage

, see the Config-

uration chapter in the Web OS 10.0 Command Reference). The hold down time is calculated
with the following equation:

Hold down time =

holddur

x

slowage

If

slowage

is set to the default value of 0 (2 minutes), then the configured value for hold

down time is

Hold down time = 2 x 2 = 4 minutes

If a client exceeds the TCP rate limit, then the client is not allowed to make any new TCP con-
nections for 4 minutes.

The following two configuration examples illustrate how to use TCP rate limiting to limit user
access based on source IP address and virtual IP address.

>> # /cfg/slb/adv/timewin 3

(Set the time window)

>> # /cfg/slb/adv/holddur 2

(Set the hold duration)