Web OS 10.0 Application Guide

Chapter 2: VLANs

n

47

212777-A, February 2002

N

OTE

VLAN tagging is required only on ports that are connected to other Alteon Web

switches or on ports that connect to tag-capable end-stations, such as servers with VLAN-
tagging adapters.

PCs #1 and #2

These PCs are attached to a shared media hub that is then connected to
the switch. They belong to VLAN 2 and are logically in the same IP
subnet as Server 2 and PC 5. Tagging is not enabled on their switch
port.

PC #3

A member of VLAN 1, this PC can only communicate with Server 2
and PC 5.

PC #4

A member of VLAN 3, this PC can only communicate with Server 1
and Server 2.

PC #5

A member of both VLAN 1 and VLAN 2, this PC has VLAN-tagging
Gigabit Ethernet adapter installed. It can communicate with Server #2
via VLAN 1, and to PC #1 and PC #2 via VLAN 2. The switch port to
which it is connected is configured for both VLAN 1 and VLAN 2 and
has tagging enabled.