immediately after turning on the AC power, or mounting a PCI module. The mirror of
a disk may be removed if you turn on the power and start the server before or during
the duplication process. Make sure to start the server after the duplication process of
BMC is completed.
You can check the status of the duplication process from BMC status LED of PCI
module on mounted side.

• Illuminating red:

Yet to be duplicated

• Blinking in red:

In the process of duplication

• Off: Duplication

is

completed

See “LEDs” in Chapter 2 “General Description” for details of the BMC status
LED.

Memory dump (debug information) cannot be collected at a failure occurrence:

Is there any available space at the memory dump storage location?

Specify a drive in which there is an available storage space of greater than a memory
size on the server plus 12 MB (more than 2048 + 12MB if a memory size is more than
2GB ).

For details, see “Set Memory Dump (Debug Information)” of “Step 12: Set up
Failure Management” in Chapter 4 “Windows Setup” in the separate User’s Guide for
setup.

Is [Initial size] of the paging file of the OS partition smaller than [Recommended]?

If a value smaller than the [Recommended] value is set for [Initial Size] of the paging
file, accurate memory dump (debug information) may not be collected. Be sure to
create the file in the above size in the OS partition.
For details, see “Set Memory Dump (Debug Information)” of “Step 12: Set up
Failure Management” in Chapter 4 “Windows Setup” in the separate User’s Guide for
setup.