/cfg/l3/igmp/relay

IGMP Relay Configuration

Table 6-85

describes the commands used to configure IGMP Relay.

dis

Disables IGMP version 3.

cur

Displays the current IGMP version 3 configuration.

[IGMP Relay Menu]

mrtr - Upstream Multicast Router Menu

add - Add VLAN(s) to downstream

rem - Remove VLAN(s) from downstream

clear - Remove all VLAN(s) from downstream

report - Set unsolicited report interval

ena - Enable IGMP Relay

dis - Disable IGMP Relay

cur - Display current IGMP Relay configuration

Table 6-84 IGMP Relay Menu Options (/cfg/l3/igmp/relay)

Command Syntax and Usage

mrtr

<multicast router number (1-2)>

Displays the Upstream Multicast Router Menu. To view menu options, see

page 291

.

add

<VLAN number (1-4094)>

Adds the VLAN to the list of IGMP Relay VLANs.

rem

<VLAN number (1-4094)>

Removes the VLAN from the list of IGMP Relay VLANs.

clear

Removes all VLANs from the list of IGMP Relay VLANs.

report

<0-150>

Configures the interval between unsolicited Join reports sent by the switch, in seconds.

The default value is 10.

ena

Enables IGMP Relay.

Table 6-83 IGMP V3 Menu Options (/cfg/l3/igmp/snoop/igmpv3)

Command Syntax and Usage