background image

Alteon OS Command Reference

70

„

The Information Menu

BMD00007, November 2007

/info/sys/general

General System Information

N

OTE

The display of temperature will come up only if the temperature of any of the sensors

exceeds the temperature threshold. There will be a warning from the software if any of the sen-
sors exceeds this temperature threshold. The switch will shut down if the power supply over-
heats.

System information includes:

„

System date and time

„

Switch model

„

Switch name and location

„

Time of last boot

„

MAC address of the switch management processor

System Information at 0:16:42 Wed Jan 3, 2007

Time zone: No timezone configured

Nortel 10Gb Uplink Ethernet Switch Module

Switch is up 5 days, 2 hours, 16 minutes and 42 seconds.

Last boot: 0:00:47 Wed Jan 3, 2007 (power cycle)

MAC address: 00:11:58:ad:a3:00 Management IP Address (if 128):

10.90.90.97

Software Version 1.2.0 (FLASH image1), factory default configura-

tion.

PCBA Part Number: 317857-A

FAB Number: EL4512011

Serial Number: YJ1WDW47N277

Manufacturing Date:

Hardware Revision: 0

Board Revision: 0

PLD Firmware Version: 5.0

Temperature Sensor 1 (Warning): 42.5 C (Warn at 85.0 C/

Recover at 79.0 C)

Temperature Sensor 2 (Shutdown): 44.0 C (Warn at 93.0 C/

Recover at 86.0 C)

Temperature Sensor 3 (Exhaust): 42.5 C

Temperature Sensor 4 (Inlet): 42.5 C

Switch is in I/O Module Bay 0