General layers tab, General layers tab -24, Maximum vias per net – National Instruments Graphical User Interface Ultiboard User Manual

Page 40: Surface mount pads oversize

Advertising
background image

Chapter 1

User Interface

NI Ultiboard User Manual

1-24

ni.com

The Capture Land Diameter field determines the land diameter where the
microvia starts, while Target Land Diameter determines the diameter
where the microvia ends. These terms are in accordance with the IPC and
JPCA joint standard IPC/JPCA-2315, Design Guide for High Density
Interconnects (HDI) and Microvias. The Maximum Layer Span is either
one or two layers.

Maximum Vias Per Net

The Nets area is where you set up the maximum number of vias allowed
per net.

Surface Mount Pads Oversize

Depending on the manufacturing process you are using, you may wish to
enlarge the size of all surface mount pads by a fixed amount. This can be
set independently for the Top and Bottom layers. The setting refers to the
amount that will be added to the pad. In the case of a circular pad this
amount is added to the radius. In the case of a rectangular or square pad the
amount will be added to the width and length.

General Layers Tab

Use the General Layers tab of the PCB Properties dialog box to control
which layers are available on the board.

Complete the following steps to control the numbers of layers in the board:

1.

Add layers to the board by selecting the checkbox beside the layer
name.

2.

Remove layers from the board by clearing the checkbox beside the
layer name.

Note

You can have a layer available on the board, and temporarily dim or hide it. Refer to

the

Accessing Layers

section of Chapter 3,

Setting Up a Design

, for more information.

Note

There are up to ten mechanical CAD layers in PCB design. These layers allow you

to provide information that is directly related to the PCB. You place elements on them to
represent the mechanical elements of your design – for example, cabinet casing or
mounting brackets.