18

D I A G N O S I N G A N I S S U E

Troubleshooting:

F1: BLOWER (Blower Running Status Bad)

NO

NO

YES

NO

YES

NO

YES

YES

NO

T O

F R O M

D E S C R I P T I O N

E X P E C T E D R E S I S TA N C E

Black

Red

Winding (A-B)

2.0-2.6 Ohms

Black

White

Winding (A-C)

2.0-2.6 Ohms

Red

White

Winding (B-C)

2.0-2.6 Ohms

Black, Red or White

Green

Windings to Chassis

Open

        : Motor Windings Resistance Table

Is the wiring

harness properly

connected?

Check the Motor

Controller, Blower

Motor, and I/O

Control Board.

(See page 61 for

schematic.)

Replace Blower

Motor. (page 53)

Correct the wiring

or replace I/O Control
Board (page 39)/Motor

Controller (page 32)

if damaged.

Is Status Indicator A backlit

on the “Test” Screen?

(see page 23)

Is the Blower Motor

spinning freely?

Do resistance measurements

between windings and chassis

agree with values on Motor

Windings Resistance Table?

(Figure 24, below)

Replace Blower

Motor (page 53) or

remove obstruction.

Replace

Motor Controller.

(page 32)