D I A G N O S I N G A N I S S U E

S TAT U S I N D I C AT O R S

Displayed in Test and Diagnostic Modes, Status
Indicators help in troubleshooting. The following
oven parts are represented by letters at the bottom
of the display (Figure 26).

Door (represented by “D”)

Backlit = OPEN
Not backlit = CLOSED

Heater A (represented by left “H”)

Backlit = OFF
Not backlit = ON

Heater B (represented by right “H”)

Backlit = OFF
Not Backlit = ON

Blower (represented by “A” for “air”)

Backlit = OFF
Not Backlit = ON

NOTE: In Figure 26, the door is open (the “D”
is backlit), Heater A and B are on (neither “H” is
backlit) and the Blower is off (the “A” is backlit).

T E S T I N G O P T I O N S

From the Test Mode Menu (Figure 26), a service
technician can test/reference the following oven
components:

Blower Motor
Fault Log
Temperature Offset
Heaters A & B
Rack Oscillator
Diagnostic Mode
Cook Counter/Time
Cumulative Operating Time
Electrical Compartment Temperature
Fahrenheit/Celsius Options
Serial Number

To access the Test Mode Menu:
1. Ensure the oven is in the Off or Cool-down

State.

2. Simultaneously press and hold the “Down” and

“Right” Keys for 1 second.

NOTE: The Test Mode Menu contains two
screens. Use the “UP” and “DOWN” Keys to toggle
from screen to screen.

LEFT

RIGHT

        : Test Mode Menu, Screen 1 of 2