D I A G N O S I N G A N I S S U E

NOTE: Adjustments can be made only in
Fahrenheit. (5ºF equals approximately 2.8ºC.)

NOTE: At 20°F, pressing the “OFFSET” Soft Key
rolls the Temperature Offset back to 0°F.

3. Press “ENTER” to confirm.

4. When finished, press the “BACK/STOP” Key to

exit the Test Mode Menu.

Checking Heaters A and B (Figures 30-31)

NOTE: If the Blower Speed is “0”, the Blower will
automatically set to idle airflow at the initiation of
this test.

To turn on Heater A: (Figure 30)
1. From Screen 1 of the Test Mode Menu, press

the “HEATER A” Soft Key (top right).

2. When finished testing, press the “HEATER A”

Soft Key (top right) to turn Heater A off.

3. Press the “BACK/STOP” Key to end the test

and exit the Test Mode Menu.

To turn on Heater B: (Figure 31, page 26)
1. From Screen 1 of the Test Mode Menu, press

the “HEATER B” Soft Key (middle right).

2. When finished testing, press the “HEATER B”

Soft Key (middle right) to turn Heater B off.

3. Press the “BACK/STOP” Key to end the test

and exit the Test Mode Menu.

LEFT

RIGHT

        : Adjusting the Temperature Offset

Step: 1/2

Step: 3

Simultaneously press and hold for 1
second to get to the Test Mode Menu
(Screen 1). NOTE: Oven must be in
the Off or Cool-down State.

In this example, the Temperature Offset is
set at 20ºF (approximately 11ºC).

LEFT

RIGHT

        : Checking Heater A

Step: 1/2

Step: 3

Simultaneously press and hold for 1
second to get to the Test Mode Menu
(Screen 1). NOTE: Oven must be in
the Off or Cool-down State.

In this example, Heater A is on.

25