F6: EC TEMP (Electrical Compartment (EC)

Temperature High)

This fault displays if the Electrical Compartment
(EC) temperature exceeds 158°F (70°C). The
Control System checks the EC Thermocouple
once per minute.

NOTE: This fault will not terminate a Cook Cycle.

To clear this fault:
The EC temperature must recede below
158°F (70°C).

Troubleshooting: F6 Fault
To troubleshoot an F6 Fault, see the diagram
on page 21.

F7: THERMO (Thermocouple Open)

This fault will display if the Control System
detects that the CC Thermocouple is “Open,”
or 999°F/C.

To clear this fault:
The Control System must detect continuity on
the thermocouple circuit.

Troubleshooting: F7 Fault
To troubleshoot an F7 Fault, see the diagram
on page 21.

F8: HEAT LOW

This fault will display if during warm-up the
Cook Chamber temperature fails to rise at least
35°F (approximately 18ºC) every five minutes.

NOTE: This fault will not log; rather it will
display an Error Message during warm-up.

Troubleshooting: F8 Fault
To troubleshoot an F8 Fault, see the diagram
on page 22.

20

        : Location of Hi-Limit Thermostat Reset Button