TurboChef Technologies High h Batch User Manual

Page 40

Advertising
background image

D I A G N O S I N G A N I S S U E

Testing the Blower Motor (Figure 27)

1. From Screen 1 of the Test Mode Menu, press

the “BLOWER” Soft Key (top left).

2. Continue pressing the “BLOWER” Soft Key (top

left) to raise blower speed in 10% increments.

3. When finished, press the “BACK/STOP” Key to

end the test and exit the Test Mode Menu.

Viewing/Clearing the Fault Log (Figure 28)

1. From Screen 1 of the Test Mode Menu, press

the “FAULTS” Soft Key (middle left).

2. To zero-out the Fault Log, press the “Enter” key.

3. When finished, press the “BACK/STOP” Key to

exit the Test Mode Menu.

Adjusting the Temperature Offset (Figure 29)

The Temperature Offset is a feature that ensures
accurate temperature readings where the food actually
cooks, as opposed to where the thermocouple is.

The value entered for temperature offset will
deduct from the oven’s temperature reading. For
example, if the oven temperature = 500ºF, and the
temperature offset is 20ºF, the oven will display
480ºF.

To adjust the Temperature Offset:
1. From Screen 1 of the Test Mode Menu, press

the “OFFSET” Soft Key (bottom left).

2. Continue pressing the “OFFSET” Soft Key to

adjust the Temperature Offset in 5°F increments.

LEFT

RIGHT

        : Viewing the Fault Log

Step: 1

Step: 2

Simultaneously press and hold for 1
second to get to the Test Mode Menu
(Screen 1). NOTE: Oven must be in
the Off or Cool-down State.

In this example, test shows the oven has
logged one (1) F1 Fault.

LEFT

RIGHT

        : Testing the Blower Motor

Step: 1/2

Step: 3

Simultaneously press and hold for 1
second to get to the Test Mode Menu
(Screen 1). NOTE: Oven must be in
the Off or Cool-down State.

Airflow increases 10%
each time the “BLOWER”
Soft Key is pressed.

Status Indicator “A”
should not be backlit.

24

Step: 3

Advertising