54

T H E I M P I N G E M E N T C I R C U I T

Heater Element (Figure 56)

Sheathed-style/Calrod heaters. Attached to the
same cartridge, Heaters A and B can be tested
independently of one another.

To replace a defective heater:
1. Ensure “Cool Down” process is completed (“Cool

Down” message will disappear upon completion)
and unplug the oven.

2. Remove Right Side Panel.

3. Disconnect Wiring Harness from heaters.

4. Remove Insulation Shield.

5. Pull back insulation where necessary.

6. Replace defective heater cartridge with

P/N HHB-8099.

a. Tighten flange nut
b. Reconnect Wiring Harness
c. Tighten jam nut

CAUTION: An over-tightened flange nut
may cause heater failure. To prevent heater

failure, hold a wrench to the flange nut to keep it
in place when tightening the jam nut. This ensures
the jam nut tightens to the flange nut, rather than
the flange nut tightening more than it should.

7. Reset insulation.

N U M B E R

PA R T PA R T

N U M B E R

75

Nut (Jam) – Heater Element (x4)

102963

76

Nut (Flange) – Heater Element (x4)

100903

77

Heater Insulation Shield

HHB-8097

78

Screw – Heater Element (x6)

101688

79

Heater Element

HHB-8099