D I A G N O S I N G A N I S S U E

Troubleshooting:

F2: LOW TMP (Cook Temperature Low)

YES

NO

Is wiring from the

Door Switch to the I/O

Control Board OK?

(See page 61 for

schematic.)

Replace Door Switch.

(page 36)

If problem

persists, replace the

I/O Control Board.

(page 39)

Does the Display read “Cook Door

Open” when the door is closed?

YES

NO

YES

Ensure jam nut is

adequately tightened

and flange nut

(behind jam nut) is

not over-tightened.

If the problem

persists, replace the

defective heater.

(page 54)

Replace SSR.

(page 40)

NO

YES

YES

Replace I/O Control

Board. (page 39)

Correct wiring.

YES

NO

Reset and determine

why it tripped – excess

grease buildup, etc.

(Figure 25, page 20)

Is the Heater Element

defective?

Is the Hi-Limit

Thermostat tripped?

Is the SSR defective?

Is wiring from

SSR to I/O Control

Board OK?

(See page 61 for

schematic.)

Correct wiring.