UNICOM

52

Default is 300 seconds.

Max bridge transmit delay bound control: Limits the packet queuing time in the
switch. If enabled, any packets exceeding queue will be dropped. The valid values are
1sec, 2 sec, 4 sec, and off.
Enable Low Queue Delay Bound: Limits the low priority packet queuing time in the
switch. If the low priority packets stay in the switch over the Max Delay Time, they will
automatically be sent. The valid range is 1~255 ms.

NOTE: Make sure that “Max bridge transit delay bound control” is enabled before enabling
Delay Bound”.

Broadcast Storm Filter: To configure broadcast storm control, enable it and set the
upper threshold for individual ports. The threshold is the percentage of the port's total
bandwidth used by broadcast traffic. When broadcast traffic for a port rises above the
threshold you set, broadcast storm control becomes active. The valid threshold values
are 5%, 10%, 15%, 20%, 25% and off.

Priority Queue Service settings:

First Come First Service: The sequence of packets sent depends on their arrival
order.
All High before Low: All high priority packets are sent before low priority packets.
WRR (Weighted Round Ratio): Selects the preference given to packets in the switch's

Advertising