Rack-mounted Installation

The SmartGST-2402M comes with a rack-mounting kit and can be mounted in an
EIA standard sized, 19-inch Rack. The Switch can be placed in a wiring closet with
other equipment.

Perform the following steps to rack mount the switch:

A.

Align one bracket with the holes on one side of the switch and secure it with the
smaller bracket screws. Then attach the remaining bracket to the other side of
the Switch.

Figure 2-4. Attach mounting brackets with screws

B.

After you’ve attached both mounting brackets, position the SmartGST-2402M in
the rack by lining up the holes in the brackets with the appropriate holes on the
rack. Secure the Switch to the rack with a screwdriver and the rack-mounting
screws.

Figure 2-5. Mount the

SmartGST-2402M

in a standard 19-inch Rack

Note:

For proper ventilation, allow about at least 4 inches ( 10 cm ) of clearance on the
front and 3.4 inches ( 8 cm ) on the back of the Switch. This is especially important
for enclosed rack installation.