WHP Wireless DL360 User Manual

Page 118

Advertising
background image

118

HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide



server documentation for further requirements.

NOTE: It is recommended that no more than two DLT drives per bus
exist.

If using an external DLT drive that requires a SCSI terminator to be secured
to the unused SCSI IN connector on the back of the drive, be sure the SCSI
terminator is connected.

DLT drives can be daisy chained, but do not connect more than three units
per SCSI controller. The last DLT drive in the chain requires the SCSI
terminator.

Check cables for damaged or bent connectors.

An error occurs during backup, but the backup is completed

Action: Contact the software vendor for more information about the message. If
the error does not disrupt the backup, you may be able to ignore the error.

Fan Problems

List of Problems:

General fan problems are occurring ...........................................................................................

118

Hot-plug fan problems are occurring..........................................................................................

119

General fan problems are occurring

Action:

1. Be sure the fans are properly seated and working.

a. Follow the procedures and warnings in the server documentation for

removing the access panels and accessing and replacing fans.

b. Unseat, and then reseat, each fan according to the proper procedures.

c. Replace the access panels, and then attempt to restart the server.

2. Be sure the fan configuration meets the functional requirements of the server.

Refer to the server documentation.

3. Be sure no ventilation problems exist. If you have been operating the server

for an extended period of time with the access panel removed, airflow may
have been impeded, causing thermal damage to components. Refer to the