Controller is not configured, Controller reported post error. error code: x, Controller restarted with a signature of zero – WHP Wireless DL360 User Manual

Page 164: Disable command issued

Advertising
background image

164

HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide

Controller Is Not Configured

Description: Controller is not configured. If the controller was previously
configured and you change drive locations, there may be a problem with
placement of the drives. ADU examines each physical drive and looks for drives
that have been moved to a different drive bay.

Action: Look for messages indicating which drives have been moved. If none are
displayed and drive swapping did not occur, run ACU to configure the controller
and server setup utility to configure NVRAM. Do not run either utility if you
believe drive swapping has occurred.

Controller Reported POST Error. Error Code: X

Description: The controller returned an error from its internal POST.

Action: Replace the controller.

Controller Restarted with a Signature of Zero

Description: ADU did not find a valid configuration signature to use to get the
data. NVRAM may not be present (unconfigured) or the signature present in
NVRAM may not match the signature on the controller.

Action: Run the server setup utility to configure the controller and NVRAM.

Disable Command Issued

Description: The issuing of the Accelerator Disable command has disabled
posted-writes. This occurred because of an operating system device driver.

Action: Restart the system. Run ACU to reinitialize the array accelerator board.



Advertising