Troubleshooting

179

Storage Enclosure on SCSI Bus X Indicated that the Fan is Degraded...

...SOLUTION: this condition usually occurs on enclosures with multiple fans and one of
those fans has failed. Replace any fans not operating properly.

Description: One or more fans in the external storage unit have failed.

Action: Replace the failed fans.

Storage Enclosure on SCSI Bus X Indicated that the Fan Module is Unplugged...

...SOLUTION: Make sure the fan module is properly connected.

Description: A fan in the external storage unit is not connected properly.

Action: Check and reseat all fan connections securely.

Storage Enclosure on SCSI Bus X - Wide SCSI Transfer Failed...

...SOLUTION: This may indicate a bad SCSI cable on bus X. Try replacing the cable.

Description: A cable on bus X has failed.

Action:

1. Replace the failed cable.

2. If the problem persists, contact an authorized service provider.

Swapped Cables or Configuration Error Detected. A Configured Array of Drives...

...was moved from another controller that supported more drives than this controller
supports.

SOLUTION: Upgrade the firmware on this controller. If this doesn’t solve the problem,
then power down system and move the drives back to the original controller.