Troubleshooting

123

4. Be sure no operating system errors are indicated.

5. Restart the server and check to see if the error message is still displayed.

6. Run Insight Diagnostics ("HP Insight Diagnostics" on page

80

) and replace

failed components as indicated.

Server fails to recognize existing memory

Action:

1. Reseat the memory.

2. Be sure the memory is configured properly. Refer to the server

documentation.

3. Be sure a memory count error ("Memory count error exists" on page

122

) did

not occur. Refer to the message displaying memory count during POST.

Server fails to recognize new memory

Action:

1. Be sure the memory is the correct type for the server and is installed

according to the server requirements. Refer to the server documentation or
HP website (

http://www.hp.com

).

2. Be sure you have not exceeded the memory limits of the server or operating

system. Refer to the server documentation.

3. Be sure no Event List error messages (on page

216

) are displayed in the IML

("Integrated Management Log" on page

80

).

4. Be sure the memory is properly seated.

5. Be sure no conflicts are occurring with existing memory. Run the server

setup utility.

6. Test the memory by installing the memory into a known working server. Be

sure the memory meets the requirements of the new server on which you are
testing the memory.

7. Replace the memory. Refer to the server documentation.