Drive time-out occurred on physical drive bay x, Drive x indicates position y, Duplicate write memory error – WHP Wireless DL360 User Manual

Page 168: Fyi: drive (bay) x is third-party supplied

Advertising
background image

168

HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide

Drive Time-Out Occurred on Physical Drive Bay X

Description: ADU issued a command to a physical drive and the command was
never acknowledged.

Action: The drive or cable may be bad. Check the other error messages on the
Diagnostics screen to determine resolution.

Drive X Indicates Position Y

Description: Message indicates a designated physical drive, which seems to be
scrambled or in a drive bay other than the one for which it was originally
configured.

Action: Examine the graphical drive representation on ADU to determine proper
drive locations. Remove drive X and place it in drive position Y. Rearrange the
drives according to the ADU instructions.

Duplicate Write Memory Error

Description: Data cannot be written to the array accelerator board in duplicate
due to the detection of parity errors. This is not a data-loss situation.

Action: Replace the array accelerator board.

Error Occurred Reading RIS Copy from SCSI Port X Drive ID

Description: An error occurred while ADU was trying to read the RIS from this
drive.

Action: HP stores the hard drive configuration information in the RIS. If multiple
errors occur, the drive may need to be replaced.

FYI: Drive (Bay) X is Third-Party Supplied

Description: Third-party supplied the installed drive.

Action: If problems exist with this drive, replace it with a supported drive.



Advertising