Troubleshooting

191

FATAL ROM ERROR: The System ROM is not Properly Programmed.

Audible Beeps: 1 long, 1 short

Possible Cause: The System ROM is not properly programmed.

Action: Replace the physical ROM part.

High Temperature Condition detected by Processor x

Audible Beeps:

Possible Cause: Ambient temperature exceeds recommended levels, fan solution
insufficient, or fans have failed.

Action: Adjust ambient temperature, install fans, or replace failed fans.

Illegal Opcode - System Halted

Audible Beeps: None

Possible Cause: The server has entered the Illegal Operator Handler because of
an unexpected event. This error is often software-related and does not necessarily
indicate a hardware issue.

Action: Run Insight Diagnostics and replace any failed components as indicated.
Be sure that all software is installed properly.

iLO Generated NMI

Audible Beeps: None

Possible Cause: The iLO controller generated an NMI.

Action: Check the iLO logs for details of the event.