HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide

209-Online Spare Memory Configuration - No Valid Banks for Online
Spare

Audible Beeps: 1 long, 1 short

Possible Cause: Two valid banks are not available to support an online spare
memory configuration.

Action: Install or reinstall DIMMs to support online spare configuration.

209-Online Spare Memory Configuration - Spare Bank is Invalid

Audible Beeps: 1 long, 1 short

Possible Cause: Installed DIMMs for online spare bank are of a size smaller than
another bank.

Action: Install or reinstall DIMMs to support online spare configuration.

212-Processor Failed, Processor X

Audible Beeps: 1 short

Possible Cause: Processor in slot X failed.

Action: Run Insight Diagnostics ("HP Insight Diagnostics" on page

80

) and

replace failed components as indicated.

214-Processor PPM Failed, Module X

Audible Beeps: None

Possible Cause: Indicated PPM failed.

Action: Run Insight Diagnostics ("HP Insight Diagnostics" on page

80

) and

replace failed components as indicated.