HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide

Processor Uncorrectable Internal Error (Slot X, Socket Y)

Event Type: Uncorrectable error

Action: Replace the processor.

Real-Time Clock Battery Failing

Event Type: System configuration battery low

Action: Replace the system configuration battery.

System AC Power Overload (Power Supply X)

Event Type: Power supply overload

Action:

1. Switch the voltage from 110 V to 220 V or add an additional power supply

(if applicable to the system).

2. If the problem persists, remove some of the installed options.

System AC Power Problem (Power Supply X)

Event Type: AC voltage problem

Action: Check for any power source problems.

System Fan Failure (Fan X, Location)

Event Type: Fan failure

Action: Replace the fan.

System Fans Not Redundant

Event Type: Fans not redundant



Action: Add a fan or replace the failed fan.