Logical drive x status = wrong drive replaced, Mirror data miscompare – WHP Wireless DL360 User Manual

Page 172

Advertising
background image

172

HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide

Logical Drive X Status = Recovering (rebuilding data on a replaced drive)

Description: A physical drive in this logical drive has failed and has now been
replaced. The replaced drive is rebuilding from the mirror drive or the parity
data.

Action: No action is required. Normal operations can occur; however,
performance will be less than optimal until after the rebuild process completes.

Logical Drive X Status = Wrong Drive Replaced

Description: A physical drive in this logical drive has failed. The incorrect drive
was replaced.

Action: Replace the drive that was incorrectly replaced. Then, replace the
original drive that failed with a new drive.

CAUTION: Do not run the server setup utility and try to

reconfigure, or data will be lost.

Loose Cable Detected - Logical Drives May Be Marked FAILED Until Corrected

Description: ADU found a loose cable. The Smart Array Controller is unable to
communicate with one or more physical drives. One or more logical drives may
be marked FAILED, and are unusable until the problem is corrected.

Action: Power down the system. Check the cables for a tight connection to the
logical drives. Restart the system. If the error persists, the cables may be
defective.

Mirror Data Miscompare

Description: Data was found at reset initialization in the posted-write memory;
however, the mirror data compare test failed resulting in that data being marked
as invalid. Data loss is possible.

Action: Replace the array accelerator board.



Advertising