Drive (Bay) X is a Replacement Drive

Description: This drive has been replaced. This message is displayed if a drive is
replaced in a fault-tolerant logical volume.

Action: If the replacement was intentional, allow the drive to rebuild.

Drive (Bay) X is a Replacement Drive Marked OK

Description: This drive has been replaced and marked OK by the firmware,
which may occur if a drive has an intermittent failure. For example, a drive has
previously failed, then starts working again when ADU is run.

Action: Replace the drive.

Drive (Bay) X is Failed

Description: The indicated physical drive has failed.

Action: Replace this drive.

Drive (Bay) X is Undergoing Drive Recovery

Description: This drive is being rebuilt from the corresponding mirror or parity
data.

Action: No action is required.

Drive (Bay) X Needs Replacing

Description: The 210-MB hard drive has firmware version 2.30 or 2.31.

Action: Replace the drive.