Querying base interface ekey status – Znyx Networks bh5700 User Manual

Page 167

Advertising
background image

10hd – Ethernet Half Duplex

Pause: Enable: a port that can temporarily suspend the data transmission
between two network devices in the event that one of the devices becomes
congested. Pause enabled devices can reduce bottlenecks by making the
network more efficient.

Disabled: The pause feature is not enabled and will continue to

transmit traffic when even when the receiving device is
busy.

Faults: Internal: An internal fault indicates a severe hardware failure

External: An external fault indicates that a port has been configured to active,

but a link has not been established.

OK: ON: Indicates that the Ethernet Switch Blade has successfully loaded

OpenArchitect.

Querying Base Interface ekey Status

Link Status for a single port

To query a link status for a single port type

zre<x> query for example:

zlc zre13 query

Example Output:

Link Status for a range of ports

To query the link status for a range of ports type

zre<x>..<x> query

for

example:

zlc zre0..23 query

Example Output:

Ethernet Switch Blade User's Guide

release 3.2.2j

page 167

sh-2.04# zlc 13 query
zre13: <UP, 100FD, PAUSE ENABLE OFF, OK ON>
sh-2.04#