Hardware subsystem – Znyx Networks bh5700 User Manual

Page 176

Advertising
background image

6. Isolation Transformer

13. Isolation Transformers

7. Power Supply

14. 4 Port PHY

Hardware Subsystem

In the following tables, refer to the identified component-area numbers on indicated in the
pictures in the proceeding section. The indications of malfunction may be identified either during
normal operation, or in response to a specific test. The various tests that may be initiated are
shown in subsequent sections.

The information is equally applicable to both the Base Interface and the Fabric Interface switch
subsystems unless otherwise noted.

Base

ZMC 0

#

ZMC 1

#

Hardware

Subsystem

Indications of Malfunction

4

3

CPU

A CPU failure may be indicated by any of the
following:

A failure to run the Power-On-Self-
Test (POST)

A failure to boot the OpenArchitect
kernel

Kernel panics

Loss of CPU response sometime after
operation is initiated

5

3

RAM

The Ethernet Switch Blade uses SDRAM for
the primary CPU memory system. A failure of
RAM will generally cause any of the
following:

Kernel panics

Loss of CPU response

Unexplained software failures

1

8

ROM

The Flash ROM subsystem on the Ethernet
Switch Blade is used only on boot-up. The
contents are decompressed and copied to RAM
memory for further use. A ROM failure will
generally cause a failure in the boot process.

9, 10

6, 7

Switch Fabric

The Ethernet Switch Blade has four switch
fabric chips: 2 for the Base Interface with 24
ports, and 2 for the Fabric Interface with 48
ports. A Switch Fabric failure may result in

Ethernet Switch Blade User's Guide

release 3.2.2j

page 176