Version 2.x supports three FRU Inventory Device Commands:

Get FRU Inventory Area Info

Read FRU Data

Write FRU Data

The spare SEEPROM space is allocated as follows:

Spare SEEPROM Space Allocation

Space for

Start address

End address

Size

Notes

VPD

0

0x3FF

0x400 (1Kbytes)

FRU

0x400

0x13FF

0x1000 (4kbytes)

Parameters

0x1400

0x17FF

0x400 (1 Kbytes)

Attribute

0x1800

0x37FF

0x2000 (8
Kbytes)

Table C.8: SEEPROM Space

IPMB Override/Local Status - Event Data 3 for the IPMB link

IPMB Override Status Data

Bit(s)

Type

Notes

7

IPMB B Override State

0=Override state, bus isolated; 1= Local Control state - IPM
Controller determines state of bus

6:4

IPMB B Local Status

0=No Failure. Bus enabled if no override in effect;
1=Unable to drive clock HI; 2=Unable to drive data HI;
3=Unable to drive clock LO; 4= Unable to drive data LO;
5= Clock low time out; 6=under test; 7=Undiagnosed
communications failure

3

IPMB A Override State

0=Override state, bus isolated; 1= Local Control state - IPM
Controller determines state of bus

2:0

IPMB A Local Status

0=No Failure. Bus enabled if no override in effect;
1=Unable to drive clock HI; 2=Unable to drive data HI;
3=Unable to drive clock LO; 4= Unable to drive data LO;