23 problem solving – Zenith Data Systems MT2000 User Manual

Page 166

Advertising
background image

6-23

Problem Solving

Table 6-3. POST Tests (continued)

Code

Beeps

POST Routine Description

88

3-1-3-1

Initialize BIOS Data Area

8A

3-1-3-3

Initialize Extended BIOS Data Area

8C

3-1-4-1

Initialize floppy controller

90

3-2-1-1

Initialize hard disk drives

91

3-2-1-2

Initialize local-bus hard-disk controller

92

3-2-1-3

Jump to UserPatch2

94

3-2-2-1

Disable A20 address line

96

3-2-2-3

Clear huge ES segment register

98

3-2-3-1

Search for option ROMs. One long, two short beeps on checksum failure

9A

3-2-3-3

Shadow option ROMs

9C

3-2-4-1

Set up Power Management

9E

3-2-4-3

Enable hardware interrupts

A0

3-3-1-1

Set time of day

A2

3-3-1-3

Check key lock

A8

3-3-3-1

Erase F2 prompt

AA

3-3-3-3

Scan for F2 keystroke

AC

3-3-4-1

Enter SETUP

AE

3-3-4-3

Clear in-POST flag

B0

3-4-1-1

Check for errors

B2

3-4-1-3

POST done - prepare to boot operating system

B4

3-4-2-1

One short beep before boot

B6

3-4-2-3

Check password (optional)

B8

3-4-3-1

Clear global descriptor table

BC

3-4-4-1

Clear parity checkers

BE

3-4-4-3

Clear screen (optional)

BF

3-4-4-4

Check virus and backup reminders

C0

4-1-1-1

Try to boot with INT 19

D0

4-2-1-1

Interrupt handler error

D2

4-2-1-3

Unknown interrupt error

D4

4-2-2-1

Pending interrupt error

D6

4-2-2-3

Initialize option ROM error

D8

4-2-3-1

Shutdown error

DA

4-2-3-3

Extended Block Move

DC

4-2-4-1

Shutdown 10 error

DE

4-2-4-3

Keyboard Controller Failure

Advertising