26 configuring your system – Zenith Data Systems MT2000 User Manual

Page 79

Advertising
background image

4-26

Configuring Your System

Situations that require changing switch settings
include the following.

using an uninterruptible power supply

Note: The switches are set correctly at the factory for
your system configuration. If your system requires a
switch change, change only the switch setting for that
condition. Otherwise keep the switches at their factory
settings.

Table 4-7 shows the switch configurations and
functions. Set the switches per Table 4-7 and the
following steps.

Table 4-7 Function Select Switch Settings

Switch

Signal

Settings

Function

SW1

RESERVED

Off (factory setting)
On

Reserved for future use.

SW2

RSTMASK

Off
On (factory setting)

Reserved for future use.

SW3

ACLINK

Off (factory setting)
On

Sets server for use with a local power source.
Sets server for use with an optional
uninterruptible power supply (UPS) unit and
disables the Power button on the front of the
server.

SW4

RESERVED

Off (factory setting)
On

Reserved for future use.

To change a switch setting, use the following
procedure.

Note: Power must be completely off before setting the
switches, otherwise the settings will not be recognized.

1.

At the front of the server, press the Power switch
off.

2.

At the rear of the server, press the Main Power
switch off.

Advertising