Miscellaneous states, Combining several twi modes, Atmega128(l) – Rainbow Electronics ATmega128L User Manual

Page 215

Advertising
background image

215

ATmega128(L)

2467B–09/01

Miscellaneous States

There are two status codes that do not correspond to a defined TWI state, see

Table 91.

Status $F8 indicates that no relevant information is available because the TWINT flag is
not set. This occurs between other states, and when the TWI is not involved in a serial
transfer.

Status $00 indicates that a bus error has occurred during a 2-wire Serial Bus transfer. A
bus error occurs when a START or STOP condition occurs at an illegal position in the
format frame. Examples of such illegal positions are during the serial transfer of an
address byte, a data byte, or an acknowledge bit. When a bus error occurs, TWINT is
set. To recover from a bus error, the TWSTO flag must set and TWINT must be cleared
by writing a logic one to it. This causes the TWI to enter the not addressed slave mode
and to clear the TWSTO flag (no other bits in TWCR are affected). The SDA and SCL
lines are released, and no STOP condition is transmitted.

Combining Several TWI
Modes

In some cases, several TWI modes must be combined in order to complete the desired
action. Consider for example reading data from a serial EEPROM. Typically, such a
transfer involves the following steps:

1.

The transfer must be initiated

2.

The EEPROM must be instructed what location should be read

3.

The reading must be performed

4.

The transfer must be finished

Note that data is transmitted both from master to slave and vice versa. The master must
instruct the slave what location it wants to read, requiring the use of the MT mode. Sub-
sequently, data must be read from the slave, implying the use of the MR mode. Thus,
the transfer direction must be changed. The master must keep control of the bus during
all these steps, and the steps should be carried out as an atomical operation. If this prin-
ciple is violated in a multimaster system, another master can alter the data pointer in the
EEPROM between steps 2 and 3, and the master will read the wrong data location.
Such a change in transfer direction is accomplished by transmitting a REPEATED
START between the transmission of the address byte and reception of the data. After a
REPEATED START, the master keeps ownership of the bus. The following figure shows
the flow in this transfer.

Figure 103. Combining Several TWI Modes to Access a Serial EEPROM

Table 91. Miscellaneous States

Status Code
(TWSR)
Prescaler Bits
are 0

Status of the 2-wire Serial Bus
and 2-wire Serial Interface Hard-
ware

Application Software Response

Next Action Taken by TWI Hardware

To/from TWDR

To TWCR

STA

STO

TWINT

TWEA

$F8

No relevant state information
available; TWINT = “0”

No TWDR action

No TWCR action

Wait or proceed current transfer

$00

Bus error due to an illegal
START or STOP condition

No TWDR action

0

1

1

X

Only the internal hardware is affected, no STOP condi-
tion is sent on the bus. In all cases, the bus is released
and TWSTO is cleared.

Master Transmitter

Master Receiver

S = START

Rs = REPEATED START

P = STOP

Transmitted from master to slave

Transmitted from slave to master

S

SLA+W

A

ADDRESS

A

Rs

SLA+R

A

DATA

A

P