FUNCTION

SELECTABLE

FIELDS

DEFAULT

SETTINGS

NOTES

“Panel Vdc voltage”

Start batteries DC

voltage setting

000/001

000

000 = 12 Vdc

001 = 24 Vdc

“Crown gear teeth”

speedometer

calibration setting

000/999

-

The value shown corresponds to

the number of teeth on the

engine’s crown gear, where the

sensor is located

“Low engine rpm

threshold”

0000/9999

2500

Engine rpm alarm threshold

“Operating hours”

0000/9999

-

Number of motor pump

operating hours, which can be

modified if boards are replaced

“Enable weekly”

Activation of self-

testing mode

000/001

000

000 = Disabled

001 = Enabled

“Enable UNI10779”

Activation of auto

shut-off mode

000/001

000

000 = Disabled

001 = Enabled

“Address 232”

Communication port

000/999

001

Specify address only for systems

with multiple control units

connected