Acl central logger – MoTeC ACL VIM User Manual

Page 34

Advertising
background image

30

Installation & Configuration

ACL Central Logger

ACL Mounting

Dimensions

Refer to Appendix Q: ACL Case Dimensions.

Attachment

Attach at the four mounting points using M3 screws. Do not over tighten
the screws to avoid twisting the case.

Vibration isolation will help prolong the unit life if the vehicle vibrates
severely.

Note The maximum internal operating temperature for the ACL is
85 °C, so it should not be mounted in a position where it will be
exposed to temperatures that will cause an internal temperature greater
than this.

Orientation

The ACL may be mounted in any orientation however the following
points should be considered.

Mount so that the connectors can be easily accessed, particularly the
5 pin communications connector, which is used for configuration and
data unload.

Mount so that the status LEDs are visible.

ACL Wiring

Pin Connection Details

Refer to Appendix P: ACL Pin List by Pin Number

Connector

The ACL uses a 22 pin Auto Sport connector for device connection and
power, and a 5 pin Auto Sport connector for PC Ethernet
communications.

Refer to Appendix M: Connector Details.

Advertising