MoTeC

Installation

&

Configuration

39

PLM Lambda Meter

One or more PLMs can be connected to the ACL via CAN. For installations
with multiple PLMs it is recommended that one PLM is configured as a
‘Master’ and the remaining units as ‘Slave’ devices.

PLM Setup

Use the separate PLM software to setup the PLM.

ACL Setup

Using ACL Manager, select Inputs | Communications to assign the PLM
template to one of the CAN sections.

Telemetry Radio System

Telemetry Radio Wiring

A telemetry radio can normally be wired to one of the RS232 ports.

Refer to the wiring details supplied with the telemetry system.

Telemetry Radio Setup

Configure the telemetry radios according to the instructions supplied with the
radios.

ACL Setup

Telemetry Output Setup

Select Functions | Telemetry to set up the channels that are to be
transmitted via telemetry.

Communications Setup

Using ACL Manager, select Inputs | Communications to assign the
Telemetry template to one of the RS232 sections.

Set the Baud Rate to suit the radio.

Note The same RS232 port can also be used to communicate with an
ECU. In this case the telemetry baud rate must be the same as the
ECU communications baud rate.