Appendix K: CAN Bus Wiring

The CAN bus should consist of a twisted pair trunk with 100R (0.25 watt)
terminating resistors at each end of the trunk.

The preferred cable for the trunk is 100R Data Cable but twisted 22# Tefzel is
usually OK.

The maximum length of the bus is 16 m (50 ft)

CAN Devices (such as MoTeC ACL, ADL2, BR2 etc) may be connected to the
trunk with up to 500 mm (20 in) of twisted wire.

CAN-LO

CAN-HI

10

0R

10
0R

CA

N-

LO

CA

N-

HI

500mm
Max

<< CAN Bus >>

100R Terminating
Resistors at each
end of the CAN Bus

CA

N-

LO

CA

N-

HI

CA

N-

LO

CA

N-

HI

These wires must be Twisted

Minimum one twist per 50 mm (2 in)

CAN Device

eg ACL

CAN Device

eg ADL2

CAN Device

eg VIM